6CYANA: atoms calibrate - CYANA command

Parameters: selection=<string>             (default: <blank>)
            peaklists=<integer range>      (default: 1..1)
            constant=<real>                (default: -1.0)
            dref=<real>                    (default: 3.4)
            volcut=<real>                  (default: 0.66)

Command to set the calibration constant of the atoms matched by
the selection <string> for the chosen <peaklists>. By default, the
selection made in the most recent 'atoms select' command is used,
or all atoms if no selection has been made so far. The calibration
constant can either be set explicitly to a given positive <constant>,
or it can be determined such as to achieve a median upper distance
limit of approximately <dref> Angstrom for the peaks assigned to
selected atoms in the <peaklists>. Only assignments to which a
fraction of the total peak volume greater than the cutoff <volcut>
is attributed are included when computing the median. This command
sets the calibration constant of atoms, which may later be used to
obtain upper distance limit restraints from assigned NOESY peaks by
the command 'peaks calibrate'.

See also: peaks calibrate, calibrate, caliba